Digital Flowmeter
Monitor compressed air usage and waste!

What Is The Digital Flowmeter?
Back To Top
EXAIR’s new Digital Flowmeter is the easy way to monitor compressed air consumption and waste! The digital display shows the exact amount of compressed air being used downstream. This makes it possible to save thousands of dollars per year in compressed air waste – helping to identify costly leaks or inefficient air products. Many companies install the Digital Flowmeter on each major leg of their air distribution system to constantly monitor and reduce compressed air usage.
Why the Digital Flowmeter?
Back To Top
The Digital Flowmeter has an LED display that directly indicates the SCFM of airflow through that pipe (other flow meters require the reading to be multiplied by a specific conversion factor to be accurate). Two models are available for use on Schedule 40 iron pipe – one designed for 1" Schedule 40 iron pipe and the other for 2". Each Digital Flowmeter is calibrated for the specific pipe size it is mounted to.
The Digital Flowmeter is designed for permanent mounting to the pipe. It requires the user to drill two 3/16" diameter holes through the pipe using the included drill bit and locating fixture. The two flow sensing probes of the flowmeter are inserted in these holes. The unit seals to the pipe once the two clamps are tightened. No cutting, welding, adjustments or calibration are ever required.
Each Digital Flowmeter comes complete with
18 VDC power supply, 3/16" drill bit, and hole
locating fixture.
Advantages
Back To Top
- Easy to install
- No moving parts
- Sensitive at low flows
- No calibration or setup required
- Includes necessary components for installation
- Two models for use on 1" and 2" Schedule 40 Iron Pipe
Specifications
Back To Top
| Model | Pipe Size | Range |
|---|---|---|
| 9092 | 1" (Schedule 40 iron) | 1 - 80 SCFM |
| 9095 | 2" (Schedule 40 iron) | 2 - 350 SCFM |
| Specifications | |
|---|---|
| Accuracy | 5% of reading. Add 1% of full scale for air temperature between 40º to 120ºF (4º to 49ºC). Accuracy will be reduced when flow is outside the specified range. |
| Operating Pressure | 30 to 140 PSIG for best accuracy - 200 PSIG max. |
| Input Power | 250 mA at 18 VDC / Power Adapter 120VAC |
| Wetted Materials | Stainless steel, gold, thermal epoxy and Viton (seal) |
| Ring Material | Aluminum |
| Display | Four-digit LED display |
| Compliance | CE and RoHS |
| Note: For use with compressed air and nitrogen only. |