{"id":62761,"date":"2023-06-16T15:14:46","date_gmt":"2023-06-16T13:14:46","guid":{"rendered":"https:\/\/www.eputec.de\/?page_id=62761"},"modified":"2026-04-16T10:01:26","modified_gmt":"2026-04-16T08:01:26","slug":"atex-cabinet-cooler","status":"publish","type":"page","link":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/","title":{"rendered":"ATEX Cabinet Cooler"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.3333333333%;--awb-margin-top-large:15px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"200\" height=\"200\" alt=\"ATEXssNOCEpr_800SQ\" title=\"ATEXssNOCEpr_800SQ\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ-200x200.jpg\" class=\"lazyload img-responsive wp-image-67922\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27800%27%20height%3D%27800%27%20viewBox%3D%270%200%20800%20800%27%3E%3Crect%20width%3D%27800%27%20height%3D%27800%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ-200x200.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ-400x400.jpg 400w, https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ-600x600.jpg 600w, https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/04\/ATEXssNOCEpr_800SQ.jpg 800w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 400px\" \/><\/span><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;width:100%;\"><\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler.png\" class=\"fusion-lightbox\" data-rel=\"iLightbox[1a10a3a36475ca0e7ab]\" data-caption=\"F\u00fcr explosions\" data-title=\"ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler\" title=\"ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler\"><img decoding=\"async\" width=\"415\" height=\"402\" alt=\"ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27415%27%20height%3D%27402%27%20viewBox%3D%270%200%20415%20402%27%3E%3Crect%20width%3D%27415%27%20height%3D%27402%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png\" class=\"lazyload img-responsive wp-image-62618\"\/><\/a><\/span><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;width:100%;\"><\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"233\" height=\"53\" alt=\"ce-osha-cmfree-ul-cus\" title=\"ce-osha-cmfree-ul-cus\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2022\/03\/ce-osha-cmfree-ul-cus.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2022\/03\/ce-osha-cmfree-ul-cus.jpg\" class=\"lazyload img-responsive wp-image-48364\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27233%27%20height%3D%2753%27%20viewBox%3D%270%200%20233%2053%27%3E%3Crect%20width%3D%27233%27%20height%3D%2753%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2022\/03\/ce-osha-cmfree-ul-cus-200x45.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2022\/03\/ce-osha-cmfree-ul-cus.jpg 233w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 233px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.6666666667%;--awb-margin-top-large:15px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h3><strong>ATEX Cabinet Cooler\u00ae &#8211; approved for Zone 2 and Zone 22 areas<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-2\"><p><strong>NEW:<\/strong> Switch cabinet cooler systems now also for hazardous areas in ATEX zones 2 and 22! Our switch cabinet coolers have now also received ATEX certification, which mainly applies to use in hazardous areas in the EU region!<\/p>\n<h3><strong>What are control cabinet coolers?<\/strong><\/h3>\n<p>Put an end to electronic control downtime due to heat, contaminants and moisture indoors or outdoors!<br \/>\nControl cabinet coolers for cooling dust- and oil-proof, splash-proof indoor and outdoor enclosures. One-way valves provide a liquid-tight seal when not in use.<\/p>\n<ul>\n<li>Deliver clean, cool air to electronic enclosures.<\/li>\n<li>Low-pressure valves maintain NEMA 4 integrity<\/li>\n<li>Constructed of aluminum and Type 303 stainless steel for long-lasting durability<\/li>\n<\/ul>\n<h3><strong>What does Zone 2\/Zone 22 mean?<\/strong><\/h3>\n<p>The potentially explosive area <strong>does not exist<\/strong> during normal operation or <strong>only exists for a short time<\/strong>.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-3\"><h3><strong>How do the conventional control cabinet coolers differ from the ATEX-certified systems?<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-4\"><p>EXAIR\u00b4s ATEX Cabinet Cooler Systems are control systems that are not purged and pressurized. Therefore they should not be relied upon neither used in place of a purged and pressurized controller. The cooler system is meant to be used in conjunction with a purged and pressurized control system!<\/p>\n<p>The maximum pressure of ATEX control panel coolers is 8.6 bar, the <strong>maximum inlet air temperature is 45 \u00b0 C<\/strong>, and cooling capacities range from 252 Kcal\/h to 1,411 Kcal\/h.<\/p>\n<p>ATEX has various area classifications. These fall under the hazardous area standard. Here, three zones are covered in two hazardous areas: gas\/liquid and dust. ATEX control cabinet coolers fall into Zone 2 for gas\/liquid and Zone 22 for dust.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-5\"><h3><strong>What are the advantages of EXAIR control cabinet coolers?<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-6\"><p>The Vortex tube included in EXAIR cabinet coolers is made of stainless steel. Stainless steel&#8217;s resistance to wear, corrosion and oxidation ensures long life and maintenance-free operation.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.6666666667%;--awb-margin-top-large:15px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-7\"><h3><strong>The sizing guide form will help you pick the right control cabinet cooler model.<\/strong><\/h3>\n<h3>Calculate cabinet cooler here &#8211; selecting the right model or size.<\/h3>\n<p>We need the technical conditions at your site to be able to offer you the right control cabinet cooler.<\/p>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;width:100%;\"><\/div><div class=\"fusion-text fusion-text-8\"><p>EXAIR control cabinet coolers are available with or without thermostat. Continuous duty coolers are recommended when constant cooling and positive pressure are desired. A thermostatically controlled model saves air because the coolers are activated only when the temperature inside has reached a critical level. Thermostatic systems are useful when heat generation is variable and constant positive pressure is not required.<\/p>\n<p>All EXAIR cabinet cooler systems include a 5 micron filter with automatic condensate drain for the compressed air supply and a hose kit to keep the cold air circulating inside the cabinet.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.3333333333%;--awb-margin-top-large:15px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><a class=\"fusion-no-lightbox\" href=\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/cabinet-cooler-sizing-guide\/\" target=\"_self\" aria-label=\"Cabinet Cooler calculation\"><img decoding=\"async\" width=\"300\" height=\"262\" alt=\"Cabinet Cooler Selecting Guide\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/Cabinet-Cooler-calculation.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/Cabinet-Cooler-calculation.jpg\" class=\"lazyload img-responsive wp-image-27517\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27262%27%20viewBox%3D%270%200%20300%20262%27%3E%3Crect%20width%3D%27300%27%20height%3D%27262%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/Cabinet-Cooler-calculation-200x175.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/Cabinet-Cooler-calculation.jpg 300w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 300px\" \/><\/a><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.6666666667%;--awb-margin-top-large:15px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-9\"><h3><strong>How do control cabinet coolers work?<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-10\"><p>Compressed air enters the vortex tube operated cabinet chiller and is split into two streams, one hot and one cold. For more information on vortex tube operation, see the &#8220;Vortex Tubes&#8221; section. The hot air from the vortex tube is damped and exits the outlet. The cold air is expelled into the cabinet through the cold air distribution set. The displaced warm air in the cabinet rises and is discharged into the atmosphere through the cabinet air outlet at a slight positive pressure. In this way, the control panel is simultaneously cooled and purged with clean, cool air. No outside air can enter the control panel at any time.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.3333333333%;--awb-margin-top-large:15px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"400\" height=\"474\" title=\"How the Cabinet Cooler works\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-400x474.jpg\" alt class=\"lazyload img-responsive wp-image-27503\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271350%27%20height%3D%271600%27%20viewBox%3D%270%200%201350%201600%27%3E%3Crect%20width%3D%271350%27%20height%3D%271600%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-200x237.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-400x474.jpg 400w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-600x711.jpg 600w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-800x948.jpg 800w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works-1200x1422.jpg 1200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/03\/How-the-Cabinet-Cooler-works.jpg 1350w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 400px\" \/><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-11\"><h3><strong>Versions<\/strong><\/h3>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.3333333333%;--awb-margin-top-large:15px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-6 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_Schaltschrankkuehler_Aluminium_150px.png\" class=\"fusion-lightbox\" data-rel=\"iLightbox[e1fd94e5d26ad220bfc]\" data-title=\"ATEX_Cabinet_Cooler_Aluminium\" title=\"ATEX_Cabinet_Cooler_Aluminium\"><img decoding=\"async\" width=\"150\" height=\"484\" alt=\"ATEX_Cabinet_Cooler_Aluminium\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27150%27%20height%3D%27484%27%20viewBox%3D%270%200%20150%20484%27%3E%3Crect%20width%3D%27150%27%20height%3D%27484%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_Schaltschrankkuehler_Aluminium_150px.png\" class=\"lazyload img-responsive wp-image-62707\"\/><\/a><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.6666666667%;--awb-margin-top-large:15px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-12\"><h3><strong>Aluminum ATEX switch cabinet cooler systems<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-13\"><p>ATEX aluminum control cabinet coolers are suitable for use in flushed electrical enclosures in the appropriate approved areas. These areas are Zone 2 and Zone 22, and they meet both UL requirements and the stringent requirements of ATEX. Particularly suitable for cooling flushed electrical panels. Cooling capacities take place from 1,000 Btu\/hr to 5,600 Btu\/hr.<\/p>\n<p>Easy installation ensured by standard electrical knockout.<\/p>\n<p>Equipment: thermostat control or continuous operation system.<\/p>\n<p>The ATEX aluminum switch cabinet coolers feature a low pressure relief valve. This closes and seals when the cooler is not in operation. This ensures integration of a NEMA 4 enclosure (dust and oil tight, splash proof, indoor\/outdoor operation).<\/p>\n<p>Each system includes a water-dirt filter separator (preventing dirt from entering the enclosure) and a cold air distribution kit (distributing air for circulation or redirection to hot spots).<\/p>\n<p>All Cabinet Coolers are CE compliant.<\/p>\n<p>The ATEX Cabinet Cooler systems are not purged and pressurized control systems. They are not a replacement for such a control system, but only in conjunction with such a system.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_3 1_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:33.3333333333%;--awb-margin-top-large:15px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-7 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_150x.png\" class=\"fusion-lightbox\" data-rel=\"iLightbox[884c9e1b094d64f9731]\" data-title=\"ATEX_Cabinet_Cooler_SS_Stainless_Steel\" title=\"ATEX_Cabinet_Cooler_SS_Stainless_Steel\"><img decoding=\"async\" width=\"150\" height=\"460\" alt=\"ATEX_Cabinet_Cooler_SS_Stainless_Steel\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27150%27%20height%3D%27460%27%20viewBox%3D%270%200%20150%20460%27%3E%3Crect%20width%3D%27150%27%20height%3D%27460%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_150x.png\" class=\"lazyload img-responsive wp-image-62646\"\/><\/a><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.6666666667%;--awb-margin-top-large:15px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-14\"><h3><strong>Stainless steel ATEX control cabinet cooler systems<\/strong><\/h3>\n<\/div><div class=\"fusion-text fusion-text-15\"><p>ATEX stainless steel control cabinet coolers are suitable for use in flushed electrical enclosures in the appropriate approved areas. These areas are Zone 2 and Zone 22, meeting both UL requirements and the stringent requirements of ATEX. Particularly suitable for cooling flushed electrical panels. Cooling capacities take place from 1,000 Btu\/hr to 5,600 Btu\/hr.<\/p>\n<p>Easy installation ensured by standard electrical knockout.<\/p>\n<p>Equipment: thermostat control or continuous operation system.<\/p>\n<p>ATEX stainless steel switch cabinet coolers feature a low pressure relief valve. This closes and seals when the cooler is not in operation. This ensures the integration of a NEMA 4 enclosure (dust and oil tight, splash proof, indoor\/outdoor operation).<\/p>\n<p>Each system includes a water-dirt filter separator (preventing dirt from entering the enclosure) and a cold air distribution kit (distributing air for circulation or redirection to hot spots).<\/p>\n<p>All Cabinet Coolers are CE compliant.<\/p>\n<p>The ATEX Cabinet Cooler systems are not purged and pressurized control systems. They are not a replacement for such a control system, but only in conjunction with such a system.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-16\"><h3><strong>More product information<\/strong><\/h3>\n<\/div><div class=\"accordian fusion-accordian\" style=\"--awb-border-size:1px;--awb-icon-size:13px;--awb-content-font-size:18px;--awb-icon-alignment:left;--awb-hover-color:#f7f7f7;--awb-border-color:rgba(204,204,204,0);--awb-background-color:#ffffff;--awb-divider-color:#eeeeee;--awb-divider-hover-color:#eeeeee;--awb-icon-color:#ffffff;--awb-title-color:#023580;--awb-content-color:#7b838b;--awb-icon-box-color:#3a4149;--awb-toggle-hover-accent-color:#023580;--awb-title-font-family:&quot;Barlow Condensed&quot;;--awb-title-font-weight:700;--awb-title-font-style:normal;--awb-title-font-size:18px;--awb-content-font-family:&quot;Barlow&quot;;--awb-content-font-style:normal;--awb-content-font-weight:400;\"><div class=\"panel-group fusion-toggle-icon-boxed\" id=\"accordion-62761-1\"><div class=\"fusion-panel panel-default panel-4e8702fd766ac01ba fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_4e8702fd766ac01ba\"><a aria-expanded=\"false\" aria-controls=\"4e8702fd766ac01ba\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#4e8702fd766ac01ba\" href=\"#4e8702fd766ac01ba\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Applications<\/span><\/a><\/h4><\/div><div id=\"4e8702fd766ac01ba\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_4e8702fd766ac01ba\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">Please click here for <a href=\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/cabinet-cooler-sizing-guide\/\">Cabinet Cooler Sizing Guide<\/a> <ul style=\"--awb-size:14px;--awb-iconcolor:#003883;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;\" class=\"fusion-checklist fusion-checklist-1 fusion-checklist-default type-icons\">\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Potentially explosive atmospheres<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Line control cabinets<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Motor control centers<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Relay panels<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">NC\/CNC systems<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Modular control centers<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">CCTV cameras<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Computer cabinets<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Cool laser housings<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Electronics scales<\/div><\/li>\n<\/ul><\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-8 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfrm1-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[e68d06afc251d1b51e5]\"><img decoding=\"async\" width=\"300\" height=\"378\" alt=\"Cabinet Coolers are compact\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfrm1.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfrm1.jpg\" class=\"lazyload img-responsive wp-image-25875\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27378%27%20viewBox%3D%270%200%20300%20378%27%3E%3Crect%20width%3D%27300%27%20height%3D%27378%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfrm1-200x252.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfrm1.jpg 300w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 300px\" \/><\/a><\/span><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-892a5969fb85d5cce fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_892a5969fb85d5cce\"><a aria-expanded=\"false\" aria-controls=\"892a5969fb85d5cce\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#892a5969fb85d5cce\" href=\"#892a5969fb85d5cce\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Advantages<\/span><\/a><\/h4><\/div><div id=\"892a5969fb85d5cce\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_892a5969fb85d5cce\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\"><ul style=\"--awb-size:14px;--awb-iconcolor:#003883;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;\" class=\"fusion-checklist fusion-checklist-2 fusion-checklist-default type-icons\">\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Low Cost<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Compact<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Quiet<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Install in minutes<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Maintain NEMA 4 integrity (IP66)<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Stabilize enclosure temperature and humidity<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">No CFC\u2019s<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Mount in standard electrical knockout<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Stop nuisance tripping<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Stop heat damaging<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Eliminate fans and filters<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Elimate lost production<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Stop circuit drift<\/div><\/li>\n<li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Stop dirt contamination<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-check\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\">Provide washdown protection<\/div><\/li>\n<\/ul><\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-9 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/cabinet-cooler-illustration-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[e225b012d5547660132]\" data-title=\"Schaltschrankk\u00fchler &#8211; Cabinet Cooler Illustration\" title=\"Schaltschrankk\u00fchler &#8211; Cabinet Coolers\"><img decoding=\"async\" width=\"300\" height=\"218\" alt=\"Cabinet Cooler Illustration\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/cabinet-cooler-illustration.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/cabinet-cooler-illustration.jpg\" class=\"lazyload img-responsive wp-image-25879\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27218%27%20viewBox%3D%270%200%20300%20218%27%3E%3Crect%20width%3D%27300%27%20height%3D%27218%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/cabinet-cooler-illustration-200x145.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/cabinet-cooler-illustration.jpg 300w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 300px\" \/><\/a><\/span><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-7d060dd7d422e6f0c fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_7d060dd7d422e6f0c\"><a aria-expanded=\"false\" aria-controls=\"7d060dd7d422e6f0c\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#7d060dd7d422e6f0c\" href=\"#7d060dd7d422e6f0c\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Comparison of serveral cooling options<\/span><\/a><\/h4><\/div><div id=\"7d060dd7d422e6f0c\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_7d060dd7d422e6f0c\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<h3 class=\"fusion-responsive-typography-calculated\" data-fontsize=\"19.8\" data-lineheight=\"23.7667px\">Heat can stop your machines<\/h3>\n<p>It happens when you least expect it. High temperatures can cook the electronics that control your machines, resulting in erroneous readings, trip-outs or fried circuit boards. Cooling the electrical cabinet can eliminate these problems, but how will you do it?<\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-10 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfanpanel-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[123c55e449904120bf6]\" data-title=\"Gef\u00e4hrliche K\u00fchlung mittels L\u00fcfter -Dangerous Fan Cooled Electrical Panel\" title=\"Gef\u00e4hrliche K\u00fchlung mittels L\u00fcfter -Dangerous Fan Cooled Electrical Panel\"><img decoding=\"async\" width=\"300\" height=\"420\" alt=\"Hitze kann Ihre Maschinen zum Stillstand bringen. Es besteht eine hohe Schockgefahr, wenn die Schalttafelt\u00fcr ge\u00f6ffnet wird und ein Ventilator hei\u00dfe, schmutzige Fabrikluft auf die Elektronik bl\u00e4st.\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfanpanel.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfanpanel.jpg\" class=\"lazyload img-responsive wp-image-25841\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27420%27%20viewBox%3D%270%200%20300%20420%27%3E%3Crect%20width%3D%27300%27%20height%3D%27420%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfanpanel-200x280.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccfanpanel.jpg 300w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 300px\" \/><\/a><\/span><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<h3>Heat Exchangers and Heat Pipes<\/h3>\n<p>These have serious limitations when it comes to summer time heat. In many cases, the temperature of the hot plant on a summer day is close to that inside the enclosure. There is not enough difference in temperature for a decent heat exchange.<\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-11 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccheatexdraw-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[9d3bfb0823153b63b96]\"><img decoding=\"async\" width=\"133\" height=\"200\" alt=\"W\u00e4rmetauscher und W\u00e4rmerohre\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27133%27%20height%3D%27200%27%20viewBox%3D%270%200%20133%20200%27%3E%3Crect%20width%3D%27133%27%20height%3D%27200%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccheatexdraw.jpg\" class=\"lazyload img-responsive wp-image-25845\"\/><\/a><\/span><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<h3>Refrigerant Panel Air Conditioners<\/h3>\n<p>These coolers are expensive, take almost a day to install, and are prone to failure when dust and dirt clogs the filter. Vibration from machinery contributes to component failures and loss of freon. Life expectancy for most compressors is rated at 2.5 years of continuous operation. Average replacement cost for a bad compressor is $750 plus installation. Often, a floor drain is not readily available for the condensation tube.<\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-12 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccrefrigdraw-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[65a6377327d2d8913f0]\"><img decoding=\"async\" width=\"131\" height=\"200\" alt=\"Klimaanlagen mit K\u00fchlmitteleinheit\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27131%27%20height%3D%27200%27%20viewBox%3D%270%200%20131%20200%27%3E%3Crect%20width%3D%27131%27%20height%3D%27200%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccrefrigdraw.jpg\" class=\"lazyload img-responsive wp-image-25849\"\/><\/a><\/span><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<h3>EXAIR Cabinet Cooler<\/h3>\n<p>Our compressed air operated Cabinet Coolers are the low cost solution. NEMA 12, 4 and 4X models are available that are very compact and mount in just minutes through an ordinary electrical knockout. Thermostat control limits compressed air use by operating the Cabinet Cooler only when the temperature inside the enclosure reaches critical levels.<\/p>\n<p>Heat exchangers, heat pipes and refrigerant coolers all have filters that can clog. Left unattended, mechanical failure of the cooler is likely. And, the expensive equipment in the electrical enclosure can malfunction, overheat and shut down the entire machine or process. EXAIR Cabinet Coolers have no moving parts to wear out and do not require constant monitoring. All models are UL Listed and available in a large number of styles and cooling capacities.<\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-13 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccdrawwide-g.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[e874683d6e9727c06e4]\"><img decoding=\"async\" width=\"69\" height=\"200\" alt=\"druckluftbetriebenen Schaltschrankk\u00fchler\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%2769%27%20height%3D%27200%27%20viewBox%3D%270%200%2069%20200%27%3E%3Crect%20width%3D%2769%27%20height%3D%27200%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/ccdrawwide.jpg\" class=\"lazyload img-responsive wp-image-25853\"\/><\/a><\/span><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-292da35494b90f9e3 fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_292da35494b90f9e3\"><a aria-expanded=\"false\" aria-controls=\"292da35494b90f9e3\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#292da35494b90f9e3\" href=\"#292da35494b90f9e3\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Models and Performance<\/span><\/a><\/h4><\/div><div id=\"292da35494b90f9e3\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_292da35494b90f9e3\"><div class=\"panel-body toggle-content fusion-clearfix\">BSP-Thread available\u00a0\u2013 <a href=\"https:\/\/www.eputec.de\/en\/contact\/\">please contact us.<\/a><\/p>\n<div class=\"fusion-table table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"6\">ATEX Cabinet Cooler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Cooling Watt<\/td>\n<td>Capacity Btu\/hr.<\/td>\n<td>Capacity Kcal\/h<\/td>\n<td>Inlet<\/td>\n<td>Sound level dBA<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4615 to ATEX4640 (Cabinet Cooler only) &#8211; Aluminium<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 821<\/td>\n<td>1.000 &#8211; 2.800<\/td>\n<td>252 &#8211; 706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4615<\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4625<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4630<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4640<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4715 to ATEX4780 (Cabinet Cooler Systems) &#8211; Aluminium<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4715<\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4725<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4730<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4740<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4750<\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4760<\/td>\n<td>1.171<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4770<\/td>\n<td>1.406<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4780<\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4815 to ATEX4880 (Cabinet Cooler Systems with Thermostat, 120V\/240V\/24VDC) &#8211; Aluminium<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4815\/ATEX4815-240\/ATEX4815-24VDC<\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4825\/ATEX4825-240\/ATEX4830-24VDC<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4830\/ATEX4830-240\/ATEX4830-24VDC<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4840\/ATEX4840-240\/ATEX4840-24VDC<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4850\/ATEX4850-240\/ATEX4850-24VDC<\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4860\/ATEX4860-240\/ATEX4860-24VDC<\/td>\n<td>1.008<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4870\/ATEX4870-240\/ATEX4870-24VDC<\/td>\n<td>1.210<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4880\/ATEX4880-240\/ATEX4880-24VDC<\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4615SS to ATEX4640SS\/ATEX4715SS to ATEX4780SS &#8211; Stainless Steel, NEMA 4X integrity<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4615SS\/ATEX4715SS<strong><br \/>\n<\/strong><\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4625SS\/ATEX4725SS<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4630SS\/ATEX4730SS<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4640SS\/ATEX4740SS<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4750SS<strong><br \/>\n<\/strong><\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4760SS<strong><br \/>\n<\/strong><\/td>\n<td>1.008<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4770SS<strong><br \/>\n<\/strong><\/td>\n<td>1.210<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4780SS<strong><br \/>\n<\/strong><\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4815SS to ATEX4880SS\/ATEX4815SS-240 to ATEX4880SS-240\/ATEX4815SS-24VDC to ATEX4880SS-24VDC &#8211; Stainless Steel, NEMA 4X integrity<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4815SS\/ATEX4815SS-240\/ATEX4815SS-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4825SS\/ATEX4825SS-240\/ATEX4825SS-24VDC<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4830SS\/ATEX4830SS-240\/ATEX4830SS-24VDC<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4840SS\/ATEX4840SS-240\/ATEX4840SS-24VDC<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4850SS\/ATEX4850SS-240\/ATEX4850SS-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4860SS\/ATEX4860SS-240\/ATEX4860SS-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.008<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4870SS\/ATEX4870SS-240\/ATEX4870SS-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.210<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4880SS\/ATEX4880SS-240\/ATEX4880SS-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4615SS-316 to ATEX4640SS-316\/ATEX4715SS-316 to ATEX4780SS-316 &#8211; Stainless Steel, NEMA 4X integrity<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4615SS-316\/ATEX4715SS-316<strong><br \/>\n<\/strong><\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4625SS-316\/ATEX4725SS-316<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4630SS-316\/ATEX4730SS-316<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4640SS-316\/ATEX4740SS-316<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4750SS-316<strong><br \/>\n<\/strong><\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4760SS-316<strong><br \/>\n<\/strong><\/td>\n<td>1.008<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4770SS-316<strong><br \/>\n<\/strong><\/td>\n<td>1.210<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4780SS-316<strong><br \/>\n<\/strong><\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td><strong>ATEX4815SS-316 to ATEX4880SS-316\/ATEX4815SS-316-240 to ATEX4880SS-316-240\/ATEX4815SS-316-24VDC to ATEX4880SS-316-24VDC &#8211; Stainless Steel, NEMA 4X integrity<br \/>\n<\/strong><\/td>\n<td>293 &#8211; 1.641<\/td>\n<td>1.000 &#8211; 5.600<\/td>\n<td>252 &#8211; 1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73 &#8211; 85<\/td>\n<\/tr>\n<tr>\n<td>ATEX4815SS-316\/ATEX4815SS-316-240\/ATEX4815SS-316-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>293<\/td>\n<td>1.000<\/td>\n<td>252<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>73<\/td>\n<\/tr>\n<tr>\n<td>ATEX4825SS-316\/ATEX4825SS-316-240\/ATEX4825SS-316-24VDC<\/td>\n<td>498<\/td>\n<td>1.700<\/td>\n<td>428<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4830SS-316\/ATEX4830SS-316-240\/ATEX4830SS-316-24VDC<\/td>\n<td>586<\/td>\n<td>2.000<\/td>\n<td>504<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>ATEX4840SS-316\/ATEX4840SS-316-240\/ATEX4840SS-316-24VDC<\/td>\n<td>821<\/td>\n<td>2.800<\/td>\n<td>706<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>ATEX4850SS-316\/ATEX4850SS-316-240\/ATEX4850SS-316-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>997<\/td>\n<td>3.400<\/td>\n<td>857<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4860SS-316\/ATEX4860SS-316-240\/ATEX4860SS-316-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.008<\/td>\n<td>4.000<\/td>\n<td>1.008<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4870SS-316\/ATEX4870SS-316-240\/ATEX4870SS-316-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.210<\/td>\n<td>4.800<\/td>\n<td>1.210<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>84<\/td>\n<\/tr>\n<tr>\n<td>ATEX4880SS-316\/ATEX4880SS-316-240\/ATEX4880SS-316-24VDC<strong><br \/>\n<\/strong><\/td>\n<td>1.641<\/td>\n<td>5.600<\/td>\n<td>1.411<\/td>\n<td>1\/4&#8243; NPT<\/td>\n<td>85<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>\n<strong>Cooling Capacity at 6,9 BAR Supply Pressure.<\/strong><br \/>\nModels (except 4608) with optional cold muffler installed<br \/>\nTemperature control: No<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>\n<div class=\"fusion-table table-1\"><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-7b5a606ee28fb7c02 fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_7b5a606ee28fb7c02\"><a aria-expanded=\"false\" aria-controls=\"7b5a606ee28fb7c02\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#7b5a606ee28fb7c02\" href=\"#7b5a606ee28fb7c02\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Dimensions<\/span><\/a><\/h4><\/div><div id=\"7b5a606ee28fb7c02\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_7b5a606ee28fb7c02\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<p>Click on picture to enlarge.<\/p>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"50%\">\n<h3>Model ATEX Aluminium<\/h3>\n<div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-14 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[4de26a784c953e9968d]\" data-title=\"dim4xlg\" title=\"dim4xlg\"><img decoding=\"async\" width=\"1920\" height=\"1920\" alt=\"dim4xlg_Abmessungen_ATEX_Cabinet_Cooler\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" class=\"lazyload img-responsive wp-image-62732\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271920%27%20height%3D%271920%27%20viewBox%3D%270%200%201920%201920%27%3E%3Crect%20width%3D%271920%27%20height%3D%271920%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-200x200.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-400x400.jpg 400w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-600x600.jpg 600w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-800x800.jpg 800w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-1200x1200.jpg 1200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg 1920w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 1200px\" \/><\/a><\/span><\/div><\/td>\n<td valign=\"top\" width=\"50%\">\n<h3>Model ATEX Stainless Steel<\/h3>\n<div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-15 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[4de26a784c953e9968d]\" data-title=\"dim4xlg\" title=\"dim4xlg\"><img decoding=\"async\" width=\"1920\" height=\"1920\" alt=\"dim4xlg_Abmessungen_ATEX_Cabinet_Cooler\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg\" class=\"lazyload img-responsive wp-image-62732\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271920%27%20height%3D%271920%27%20viewBox%3D%270%200%201920%201920%27%3E%3Crect%20width%3D%271920%27%20height%3D%271920%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-200x200.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-400x400.jpg 400w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-600x600.jpg 600w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-800x800.jpg 800w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-1200x1200.jpg 1200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/dim4xlg-scaled.jpg 1920w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 1200px\" \/><\/a><\/span><\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-ffec9f532cdafdf69 fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_ffec9f532cdafdf69\"><a aria-expanded=\"false\" aria-controls=\"ffec9f532cdafdf69\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#ffec9f532cdafdf69\" href=\"#ffec9f532cdafdf69\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Accessories<\/span><\/a><\/h4><\/div><div id=\"ffec9f532cdafdf69\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_ffec9f532cdafdf69\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<p><a href=\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/cabinet-cooler-accessories\/\">Get more information about Cabinet Cooler Accessories.<\/a><\/p>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"100%\">\n<h3 class=\"fusion-responsive-typography-calculated\" data-fontsize=\"19.8\" data-lineheight=\"23.7667px\">Elektronic Temperature Control<\/h3>\n<p>The digital Electronic Temperature Control (ETC) provides precise temperature control for your electrical enclosure. It can accureately maintain a constant temperature that is slightly under the maximum rating of the electornics, permitting just enough cooling for the electronics without going so cold as to waste compressed air. The LED readout of the ETC displays the internal temperature of the electrical enclosure (\u00b0C or \u00b0F) that is constantly being monitored by a quick response thermocouple. The control activates the solenoid valce (included) when the temperature setting is exceeded. The polycarbonate plastic enclosure of the ETC is suitable for NEMA 12, 4 and 4X environments.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>\n<div class=\"fusion-table table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"3\" align=\"center\">ETC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Description<\/td>\n<\/tr>\n<tr>\n<td>9239<\/td>\n<td>ETC, 240V, 50\/60Hz, 1\/4\u2033 NPT<\/td>\n<\/tr>\n<tr>\n<td>9259<\/td>\n<td>ETC, 240V, 50\/60Hz, 1\/2\u2033 NPT<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:30px;width:100%;\"><\/div>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:30px;width:100%;\"><\/div>\n<table>\n<tbody>\n<tr>\n<td valign=\"top\" width=\"70%\">\n<h3 class=\"fusion-responsive-typography-calculated\" data-fontsize=\"19.8\" data-lineheight=\"23.7667px\">Side Mount Kits<\/h3>\n<p>EXAIR\u00b4s Side Mount Kits make mounting on the side of an electrical enclosure possible when there is limited space on the top or side. The Side Mount Kits maintain the NEMA rating of large and small NEMA Type 4. They mount in a standard electrical knockout (1-1\/2\u2033 NPS).<\/p>\n<\/td>\n<td valign=\"top\" width=\"30%\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-16 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"375\" alt=\"Side Mount Cabinet Cooler\" title=\"Seitliches Befestigungsset &#8211; Side Mount Cabinet Cooler\" src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/sidemountnew.jpg\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/sidemountnew.jpg\" class=\"lazyload img-responsive wp-image-25897\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27375%27%20viewBox%3D%270%200%20300%20375%27%3E%3Crect%20width%3D%27300%27%20height%3D%27375%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/sidemountnew-200x250.jpg 200w, https:\/\/www.eputec.de\/wp-content\/uploads\/2016\/10\/sidemountnew.jpg 300w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 300px\" \/><\/span><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>Lateral attachment of a control cabinet cooler using the side mounting set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>\n<div class=\"fusion-table table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" align=\"center\">Side Mount Kits for Cabinet Coolers<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Description<\/td>\n<\/tr>\n<tr>\n<td>4906<\/td>\n<td>90\u00b0 Side Mount Kit for NEMA 4\/4X small<\/td>\n<\/tr>\n<tr>\n<td>4907<\/td>\n<td>90\u00b0 Side Mount Kit for NEMA 4\/4X large<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;width:100%;\"><\/div>\n<h3 class=\"fusion-responsive-typography-calculated\" data-fontsize=\"19.8\" data-lineheight=\"23.7667px\">Accessories<\/h3>\n<div class=\"fusion-table table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Description<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>902380<\/td>\n<td>ATEX Solenoid, IP65, 1\/4 NPT, 120V\/60HZ<\/td>\n<\/tr>\n<tr>\n<td>902381<\/td>\n<td>ATEX Solenoid, IP65, 1\/4 NPT, 240V\/60HZ<\/td>\n<\/tr>\n<tr>\n<td>902382<\/td>\n<td>ATEX Solenoid, IP65, 1\/4 NPT, 24VDC<\/td>\n<\/tr>\n<tr>\n<td>9004<\/td>\n<td>Automatic Drain Filter Separator, 1\/4 NPT, 43 SCFM (1,359 SLPM)<\/td>\n<\/tr>\n<tr>\n<td>9027<\/td>\n<td>Oil Removal Filter for all ATEX Systems, 7-24 SCFM(198-680 SLPM), 1\/4 NPT<\/td>\n<\/tr>\n<tr>\n<td>9005<\/td>\n<td>Oil Removal Filter for all ATEX Systems, 15-37 SCFM(425-1,048 SLPM), 3\/8 NPT<\/td>\n<\/tr>\n<tr>\n<td>9006<\/td>\n<td>Oil Removal Filter for all ATEX Systems, 50-150 SCFM(1,416-4,248 SLPM), 3\/4 NPT<\/td>\n<\/tr>\n<tr>\n<td>4908<\/td>\n<td>Hardware for Dual Cabinet Cooler<\/td>\n<\/tr>\n<tr>\n<td>4902<\/td>\n<td>Muffler<\/td>\n<\/tr>\n<tr>\n<td>4904<\/td>\n<td>Cold Air Distribution Kit big<\/td>\n<\/tr>\n<tr>\n<td>4905<\/td>\n<td>Cold Air Distribution Kit small<\/td>\n<\/tr>\n<tr>\n<td>9017<\/td>\n<td>Thermostat<\/td>\n<\/tr>\n<tr>\n<td>4014413<\/td>\n<td>3\/2 Solenoid Valve 24 V GS with Temperature control, 1\/4\u2033, flow rate 1300 l\/min<\/td>\n<\/tr>\n<tr>\n<td>4014416<\/td>\n<td>3\/2 Solenoid Valve 220\u2026240 V with Thermostat, 1\/4\u2033, flow rate 1300 l\/min at 2-8 bar<\/td>\n<\/tr>\n<tr>\n<td>4014415<\/td>\n<td>3\/2 Solenoid Valve 220 V with Thermostat, 1\/2\u2033, flow rate 4200 l\/min at 2-8 bar<\/td>\n<\/tr>\n<tr>\n<td>xxxx<\/td>\n<td>For Filters and Maintenance units please contact us.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-81eda9d63de291d20 fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_81eda9d63de291d20\"><a aria-expanded=\"false\" aria-controls=\"81eda9d63de291d20\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#81eda9d63de291d20\" href=\"#81eda9d63de291d20\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Installation and Maintenance Sheets<\/span><\/a><\/h4><\/div><div id=\"81eda9d63de291d20\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_81eda9d63de291d20\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<p><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2025\/05\/ATEX-Cabinet-Cooler_lit4016.pdf\" target=\"_blank\" rel=\"noopener\">ATEX Cabinet Cooler LIT4016<\/a><\/p>\n<p><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/UL-22-ATEX-2871X-Rev.-0.pdf\">ATEX certificate<\/a><\/p>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default panel-5f81db4b6492c5ad9 fusion-toggle-has-divider\" style=\"--awb-title-color:#023580;--awb-content-color:#7b838b;\"><div class=\"panel-heading\"><h4 class=\"panel-title toggle\" id=\"toggle_5f81db4b6492c5ad9\"><a aria-expanded=\"false\" aria-controls=\"5f81db4b6492c5ad9\" role=\"button\" data-toggle=\"collapse\" data-parent=\"#accordion-62761-1\" data-target=\"#5f81db4b6492c5ad9\" href=\"#5f81db4b6492c5ad9\"><span class=\"fusion-toggle-icon-wrapper\" aria-hidden=\"true\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-toggle-heading\">Product video<\/span><\/a><\/h4><\/div><div id=\"5f81db4b6492c5ad9\" class=\"panel-collapse collapse \" aria-labelledby=\"toggle_5f81db4b6492c5ad9\"><div class=\"panel-body toggle-content fusion-clearfix\">\n<h3>Control cabinet cooler with compressed air (Cabinet Cooler\u00ae Systeme)<\/h3>\n<h4>Control cabinet cooler &#8211; models, vortex tube principle and assembly<\/h4>\n<div class=\"fusion-video fusion-youtube\" style=\"--awb-max-width:600px;--awb-max-height:360px;\"><div class=\"video-shortcode\"><div class=\"fluid-width-video-wrapper\" style=\"padding-top:60%;\" > <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"youtube-content-blocker\" data-borlabs-cookie-content=\"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\"><div class=\"brlbs-cmpnt-cb-preset-c brlbs-cmpnt-cb-youtube\"> <div class=\"brlbs-cmpnt-cb-thumbnail\" style=\"background-image: url('https:\/\/www.eputec.de\/wp-content\/uploads\/borlabs-cookie\/1\/yt_pQmk2nf6PJ4_hqdefault.jpg')\"><\/div> <div class=\"brlbs-cmpnt-cb-main\"> <div class=\"brlbs-cmpnt-cb-play-button\"><\/div> <div class=\"brlbs-cmpnt-cb-content\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing a placeholder content from <strong>YouTube<\/strong>. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.<\/p> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">More Information<\/a> <\/div> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: inherit\">Accept required service and unblock content<\/a> <\/div> <\/div> <\/div><\/div><\/div><\/div><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;\"><\/div>\n<h4>Cabinet Cooler<\/h4>\n<div class=\"fusion-video fusion-youtube\" style=\"--awb-max-width:600px;--awb-max-height:360px;\"><div class=\"video-shortcode\"><div class=\"fluid-width-video-wrapper\" style=\"padding-top:60%;\" > <div class=\"brlbs-cmpnt-container brlbs-cmpnt-content-blocker brlbs-cmpnt-with-individual-styles\" data-borlabs-cookie-content-blocker-id=\"youtube-content-blocker\" data-borlabs-cookie-content=\"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\"><div class=\"brlbs-cmpnt-cb-preset-c brlbs-cmpnt-cb-youtube\"> <div class=\"brlbs-cmpnt-cb-thumbnail\" style=\"background-image: url('https:\/\/www.eputec.de\/wp-content\/uploads\/borlabs-cookie\/1\/yt_CoxzwJmbyxY_hqdefault.jpg')\"><\/div> <div class=\"brlbs-cmpnt-cb-main\"> <div class=\"brlbs-cmpnt-cb-play-button\"><\/div> <div class=\"brlbs-cmpnt-cb-content\"> <p class=\"brlbs-cmpnt-cb-description\">You are currently viewing a placeholder content from <strong>YouTube<\/strong>. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.<\/p> <a class=\"brlbs-cmpnt-cb-provider-toggle\" href=\"#\" data-borlabs-cookie-show-provider-information role=\"button\">More Information<\/a> <\/div> <div class=\"brlbs-cmpnt-cb-buttons\"> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-unblock role=\"button\">Unblock content<\/a> <a class=\"brlbs-cmpnt-cb-btn\" href=\"#\" data-borlabs-cookie-accept-service role=\"button\" style=\"display: inherit\">Accept required service and unblock content<\/a> <\/div> <\/div> <\/div><\/div><\/div><\/div><\/div>\n<div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;\"><\/div>\nEXAIR Cabinet Coolers cool and clean electronic cabinets cost-effectively and reliably. EXAIR Cabinet Coolers contain a vortex tube to generate cold air from compressed air &#8211; with no moving parts. The compact Cabinet Cooler can be installed into a standard cable opening within minutes.<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":10,"featured_media":62618,"parent":15460,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-62761","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ATEX Cabinet Cooler Zone 2 &amp; 22 | EPUTEC Drucklufttechnik<\/title>\n<meta name=\"description\" content=\"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ATEX Cabinet Cooler Zone 2 &amp; 22 | EPUTEC Drucklufttechnik\" \/>\n<meta property=\"og:description\" content=\"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/\" \/>\n<meta property=\"og:site_name\" content=\"EPUTEC Compressed Air Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/eputec\/?ref=ts\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T08:01:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png\" \/>\n\t<meta property=\"og:image:width\" content=\"415\" \/>\n\t<meta property=\"og:image:height\" content=\"402\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"17 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/\",\"url\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/\",\"name\":\"ATEX Cabinet Cooler Zone 2 & 22 | EPUTEC Drucklufttechnik\",\"isPartOf\":{\"@id\":\"https:\/\/www.eputec.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png\",\"datePublished\":\"2023-06-16T13:14:46+00:00\",\"dateModified\":\"2026-04-16T08:01:26+00:00\",\"description\":\"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage\",\"url\":\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png\",\"contentUrl\":\"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png\",\"width\":415,\"height\":402,\"caption\":\"F\u00fcr explosions\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.eputec.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cabinet Cooler\",\"item\":\"https:\/\/www.eputec.de\/en\/cabinet-coolers\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ATEX Cabinet Cooler\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.eputec.de\/en\/#website\",\"url\":\"https:\/\/www.eputec.de\/en\/\",\"name\":\"EPUTEC Drucklufttechnik\",\"description\":\"Compressed air nozzles and compressed air technology from EPUTEC\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.eputec.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ATEX Cabinet Cooler Zone 2 & 22 | EPUTEC Drucklufttechnik","description":"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/","og_locale":"en_US","og_type":"article","og_title":"ATEX Cabinet Cooler Zone 2 & 22 | EPUTEC Drucklufttechnik","og_description":"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.","og_url":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/","og_site_name":"EPUTEC Compressed Air Technology","article_publisher":"https:\/\/www.facebook.com\/eputec\/?ref=ts","article_modified_time":"2026-04-16T08:01:26+00:00","og_image":[{"width":415,"height":402,"url":"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"17 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/","url":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/","name":"ATEX Cabinet Cooler Zone 2 & 22 | EPUTEC Drucklufttechnik","isPartOf":{"@id":"https:\/\/www.eputec.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage"},"image":{"@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage"},"thumbnailUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png","datePublished":"2023-06-16T13:14:46+00:00","dateModified":"2026-04-16T08:01:26+00:00","description":"Our ATEX cabinet coolers are suitable for hazardous areas - available from EPUTEC Drucklufttechnik.","breadcrumb":{"@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#primaryimage","url":"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png","contentUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2023\/06\/ATEX_1Kx-415px_Cabinet_Cooler_Schaltschrankkuehler-e1769536875217.png","width":415,"height":402,"caption":"F\u00fcr explosions"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/atex-cabinet-cooler\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.eputec.de\/en\/"},{"@type":"ListItem","position":2,"name":"Cabinet Cooler","item":"https:\/\/www.eputec.de\/en\/cabinet-coolers\/"},{"@type":"ListItem","position":3,"name":"ATEX Cabinet Cooler"}]},{"@type":"WebSite","@id":"https:\/\/www.eputec.de\/en\/#website","url":"https:\/\/www.eputec.de\/en\/","name":"EPUTEC Drucklufttechnik","description":"Compressed air nozzles and compressed air technology from EPUTEC","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eputec.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/pages\/62761","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/comments?post=62761"}],"version-history":[{"count":2,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/pages\/62761\/revisions"}],"predecessor-version":[{"id":91715,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/pages\/62761\/revisions\/91715"}],"up":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/pages\/15460"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/media\/62618"}],"wp:attachment":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/media?parent=62761"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}