{"id":95038,"date":"2026-11-09T10:54:58","date_gmt":"2026-11-09T09:54:58","guid":{"rendered":"https:\/\/www.eputec.de\/not-like-this-why-the-chip-vacuum-cannot-work-here\/"},"modified":"2026-11-09T10:54:59","modified_gmt":"2026-11-09T09:54:59","slug":"not-like-this-why-the-chip-vacuum-cannot-work-here","status":"publish","type":"post","link":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/","title":{"rendered":"Not like this! Why the chip vacuum cannot work here"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:15px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><p>The <a href=\"https:\/\/www.eputec.de\/en\/en-exair-industrialhousekeeping\/exair-industriesauger-chip-vac\/chip-vac\/\">chip vacuum<\/a> from EXAIR is a great product, if you know what it can be used for. And what matters during installation&#8230;<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><p>Unfortunately, in today&#8217;s example two basic mistakes were made, which meant the &#8220;Chip Vac&#8221; chip vacuum could not function.<br \/>\nA case for EPUTEC customer service!<\/p>\n<\/div><div class=\"fusion-text fusion-text-3\"><p>First things first: this air operated vacuum was not supplied to the end customer by us but reached the user via a third party (a machine builder). As a result, we were unable to give important installation advice or a general extraction recommendation beforehand.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:15px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/exair-chip-vac-mini-fass.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[da3bf8667a6ef107db5]\" data-caption=\"Exair Chip Vac chip vacuum with mini drum, photo from a customer visit\" data-title=\"exair-chip-vac-mini-drum\" title=\"exair-chip-vac-mini-drum\"><img decoding=\"async\" width=\"800\" height=\"600\" alt=\"Exair Chip Vac chip vacuum with mini drum\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27800%27%20height%3D%27600%27%20viewBox%3D%270%200%20800%20600%27%3E%3Crect%20width%3D%27800%27%20height%3D%27600%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/exair-chip-vac-mini-fass-e1711365587910.jpg\" class=\"lazyload img-responsive wp-image-67169\"\/><\/a><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-4\"><h3>Something&#8217;s not right here! Contacting EPUTEC customer advice<\/h3>\n<\/div><div class=\"fusion-text fusion-text-5\"><p>Fortunately, the production staff eventually noticed that the normally powerful industrial vacuum was nowhere near delivering the required performance. We received a description of the problem by email: the collection bag stayed empty while the work area remained dirty. Our customer advisers found this odd, as these air operated vacuums normally work perfectly. Because of the unusual symptoms, our sales engineer decided to see for himself and promptly drove to the plant (the first photo shows the situation on arrival).<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_2_5 2_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:40%;--awb-margin-top-large:15px;--awb-spacing-right-large:4.8%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:4.8%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[b109b46b886bcdb91ab]\" data-caption=\"Chip Vac with a compressed air hose that is too small, resulting in a poor compressed air supply\" data-title=\"chip-vac-poor-compressed-air-supply\" title=\"chip-vac-poor-compressed-air-supply\"><img decoding=\"async\" width=\"450\" height=\"450\" alt=\"Chip Vac with a compressed air hose that is too small\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27450%27%20height%3D%27450%27%20viewBox%3D%270%200%20450%20450%27%3E%3Crect%20width%3D%27450%27%20height%3D%27450%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg\" class=\"lazyload img-responsive wp-image-67161\"\/><\/a><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_3_5 3_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:60%;--awb-margin-top-large:15px;--awb-spacing-right-large:3.2%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:3.2%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-6\"><h3>Where&#8217;s the air? The chip vacuum runs out of puff<\/h3>\n<\/div><div class=\"fusion-text fusion-text-7\"><p>On arrival in the production hall, the compressed air line to which the chip vacuum was connected immediately stood out. The flexible hose (see arrow) had a diameter of no more than 6 to 8\u00a0 mm, making it too small for the intended application.<\/p>\n<p>By way of explanation: in compressed air applications, as well as the operating pressure of the compressor, the volume of <strong>air delivered per unit of time<\/strong> (standard cubic metres per hour) is essential for process reliability. The same applies to the air volume actually reaching the end consumers such as air nozzles, safety air guns, etc. (standard litres per minute).<\/p>\n<p>For our Chip Vac, this means the compressed air hose must have an inside diameter of 3\/8 inch (approx. 9.5 mm) to prevent a drop in performance pressure.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1216.8px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:15px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-8\"><h3>Where are the chips? A chip vacuum with nothing to do<\/h3>\n<\/div><div class=\"fusion-text fusion-text-9\"><p>Once the compressed air supply had been sorted out, there was a second surprise when our specialist asked about the chips that a Chip Vac is normally used to extract. There were no chips anywhere to be seen.<\/p>\n<p>Instead, this machine was producing only hazardous metal dust that was so fine it could easily pass through the Chip Vac&#8217;s filter bag. We had not expected that. A chip vacuum was therefore completely out of place here and definitely not what we would have offered for this application.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:15px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><a href=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/partikel-metallbearbeitung-feinstaub-absaugen.jpg\" class=\"fusion-lightbox\" data-rel=\"iLightbox[cc598e00f6b3034c81f]\" data-caption=\"Metal dust on the floor of a workshop\" data-title=\"extracting-fine-dust-particles-metalworking\" title=\"extracting-fine-dust-particles-metalworking\"><img decoding=\"async\" width=\"500\" height=\"500\" alt=\"Metal dust on the floor of a workshop\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27500%27%20height%3D%27500%27%20viewBox%3D%270%200%20500%20500%27%3E%3Crect%20width%3D%27500%27%20height%3D%27500%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/partikel-metallbearbeitung-feinstaub-absaugen-e1711370094766.jpg\" class=\"lazyload img-responsive wp-image-67177\"\/><\/a><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:15px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:15px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-10\"><h3>We always find a solution! And sometimes even two<\/h3>\n<\/div><div class=\"fusion-text fusion-text-11\"><p>We were at least able to offer the operations manager two straightforward solutions. After a brief check of the local conditions, we recommended either retrofitting an <a href=\"https:\/\/www.eputec.de\/en\/air-amplifier-venturi-nozzle\/\" target=\"_blank\" rel=\"noopener\">Exair air amplifier<\/a> to convey the dust to the central extraction system, or alternatively an air operated <a href=\"https:\/\/www.eputec.de\/en\/industrial-vacuums-with-hepa-filter\/\" target=\"_blank\" rel=\"noopener\">industrial vacuum with HEPA filter<\/a> to protect the machine operators&#8217; airways effectively. And the unemployed Chip Vac is sure to find another place soon where it can finally show what it is capable of.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":11,"featured_media":67161,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[586,581,585],"tags":[],"class_list":["post-95038","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-compressed-air-vacuum-cleaners-blog","category-news","category-suction-cleaning-conveying-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why our chip vacuum cannot work here<\/title>\n<meta name=\"description\" content=\"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why our chip vacuum cannot work here\" \/>\n<meta property=\"og:description\" content=\"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/\" \/>\n<meta property=\"og:site_name\" content=\"EPUTEC Compressed Air Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/eputec\/?ref=ts\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-09T09:54:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-09T09:54:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/01\/eputec-wei\u00dfer-Schriftzug-Logo-klein.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"353\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Elisabeth Pietra\u00df\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elisabeth Pietra\u00df\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/\"},\"author\":{\"name\":\"Elisabeth Pietra\u00df\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#\\\/schema\\\/person\\\/b99a5a0e4cd599607f231244804b775c\"},\"headline\":\"Not like this! Why the chip vacuum cannot work here\",\"datePublished\":\"2026-11-09T09:54:58+00:00\",\"dateModified\":\"2026-11-09T09:54:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/\"},\"wordCount\":7682,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg\",\"articleSection\":[\"Compressed Air Vacuum Cleaners\",\"News\",\"Suction \\\/ Cleaning \\\/ Conveying\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/\",\"url\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/\",\"name\":\"Why our chip vacuum cannot work here\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg\",\"datePublished\":\"2026-11-09T09:54:58+00:00\",\"dateModified\":\"2026-11-09T09:54:59+00:00\",\"description\":\"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg\",\"contentUrl\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg\",\"width\":450,\"height\":450,\"caption\":\"Chip Vac with a compressed air hose that is too small, resulting in a poor compressed air supply\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/not-like-this-why-the-chip-vacuum-cannot-work-here\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Not like this! Why the chip vacuum cannot work here\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/\",\"name\":\"EPUTEC Drucklufttechnik\",\"description\":\"Compressed air nozzles and compressed air technology from EPUTEC\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#organization\",\"name\":\"EPUTEC Drucklufttechnik GmbH\",\"url\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/Logo.png\",\"contentUrl\":\"https:\\\/\\\/www.eputec.de\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/Logo.png\",\"width\":200,\"height\":70,\"caption\":\"EPUTEC Drucklufttechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/eputec\\\/?ref=ts\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/Eputec\",\"https:\\\/\\\/www.instagram.com\\\/eputecdrucklufttechnik\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/eputec\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.eputec.de\\\/en\\\/#\\\/schema\\\/person\\\/b99a5a0e4cd599607f231244804b775c\",\"name\":\"Elisabeth Pietra\u00df\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why our chip vacuum cannot work here","description":"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/","og_locale":"en_US","og_type":"article","og_title":"Why our chip vacuum cannot work here","og_description":"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog","og_url":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/","og_site_name":"EPUTEC Compressed Air Technology","article_publisher":"https:\/\/www.facebook.com\/eputec\/?ref=ts","article_published_time":"2026-11-09T09:54:58+00:00","article_modified_time":"2026-11-09T09:54:59+00:00","og_image":[{"width":500,"height":353,"url":"https:\/\/www.eputec.de\/wp-content\/uploads\/2017\/01\/eputec-wei\u00dfer-Schriftzug-Logo-klein.jpg","type":"image\/jpeg"}],"author":"Elisabeth Pietra\u00df","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elisabeth Pietra\u00df","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#article","isPartOf":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/"},"author":{"name":"Elisabeth Pietra\u00df","@id":"https:\/\/www.eputec.de\/en\/#\/schema\/person\/b99a5a0e4cd599607f231244804b775c"},"headline":"Not like this! Why the chip vacuum cannot work here","datePublished":"2026-11-09T09:54:58+00:00","dateModified":"2026-11-09T09:54:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/"},"wordCount":7682,"commentCount":0,"publisher":{"@id":"https:\/\/www.eputec.de\/en\/#organization"},"image":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#primaryimage"},"thumbnailUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg","articleSection":["Compressed Air Vacuum Cleaners","News","Suction \/ Cleaning \/ Conveying"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/","url":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/","name":"Why our chip vacuum cannot work here","isPartOf":{"@id":"https:\/\/www.eputec.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#primaryimage"},"image":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#primaryimage"},"thumbnailUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg","datePublished":"2026-11-09T09:54:58+00:00","dateModified":"2026-11-09T09:54:59+00:00","description":"The Exair chip vacuum is a great product, if you know how to use it properly. A case for our customer service team! EPUTEC Blog","breadcrumb":{"@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#primaryimage","url":"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg","contentUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2024\/03\/chip-vac-schlechte-druckluft-versorgung-e1711366526598.jpg","width":450,"height":450,"caption":"Chip Vac with a compressed air hose that is too small, resulting in a poor compressed air supply"},{"@type":"BreadcrumbList","@id":"https:\/\/www.eputec.de\/en\/not-like-this-why-the-chip-vacuum-cannot-work-here\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.eputec.de\/en\/"},{"@type":"ListItem","position":2,"name":"Not like this! Why the chip vacuum cannot work here"}]},{"@type":"WebSite","@id":"https:\/\/www.eputec.de\/en\/#website","url":"https:\/\/www.eputec.de\/en\/","name":"EPUTEC Drucklufttechnik","description":"Compressed air nozzles and compressed air technology from EPUTEC","publisher":{"@id":"https:\/\/www.eputec.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.eputec.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.eputec.de\/en\/#organization","name":"EPUTEC Drucklufttechnik GmbH","url":"https:\/\/www.eputec.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.eputec.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.eputec.de\/wp-content\/uploads\/2019\/03\/Logo.png","contentUrl":"https:\/\/www.eputec.de\/wp-content\/uploads\/2019\/03\/Logo.png","width":200,"height":70,"caption":"EPUTEC Drucklufttechnik GmbH"},"image":{"@id":"https:\/\/www.eputec.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/eputec\/?ref=ts","https:\/\/www.youtube.com\/user\/Eputec","https:\/\/www.instagram.com\/eputecdrucklufttechnik\/","https:\/\/www.linkedin.com\/company\/eputec\/"]},{"@type":"Person","@id":"https:\/\/www.eputec.de\/en\/#\/schema\/person\/b99a5a0e4cd599607f231244804b775c","name":"Elisabeth Pietra\u00df"}]}},"_links":{"self":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/posts\/95038","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/comments?post=95038"}],"version-history":[{"count":0,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/posts\/95038\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/media\/67161"}],"wp:attachment":[{"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/media?parent=95038"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/categories?post=95038"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eputec.de\/en\/wp-json\/wp\/v2\/tags?post=95038"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}